Tile-Backing Application
Purpose-sized fibre cement substrate for tiled wall applications.
Tile backing / A1 non-combustible
A1 fibre cement tile substrate for wet-area and interior tiling applications.

01 / Product overview

Smartbacker® is a compact-format fibre cement board developed for tile-backing applications. Its 800 × 1.200 mm format is suited to bathrooms, wet areas and framed wall systems where a stable, non-combustible substrate is required.
Request the latest technical documentation before final specification.
02 / Performance
Purpose-sized fibre cement substrate for tiled wall applications.
Suitable for use beneath tiles in wet-area applications.
Reaction to fire class A1 according to EN 13501-1.
No water drops observed in the declared impermeability assessment.
Declared moisture movement max. 0.20%.
800 × 1.200 mm format for practical handling and tile-backing layouts.
Type NT fibre cement construction without asbestos or asbestos compounds.
Suitable for backer-board applications within framed construction systems.
03 / Data
Declared properties and standard formats.
| Property | Declared performance | Reference / standard |
|---|---|---|
| Reaction to fire | A1 — non-combustible | EN 13501-1 |
| Type / category / class | NT / Category A / Class 2 | EN 12467+A2:2018 |
| Apparent density | ≥ 1.350 kg/m³ | EN 12467+A2:2018 |
| Bending strength | ≥ 7 N/mm² Wet condition — Category A/B | EN 12467+A2:2018 |
| Elastic performance | ≥ 8.000 N/mm² — length ≥ 6.000 N/mm² — width | EN 12467+A2:2018 |
| Water impermeability | No water drops observed | EN 12467+A2:2018 |
Declared values are based on the current fibre cement technical documentation. Project-specific suitability, fixing, jointing and waterproofing requirements should be verified for the complete installation system before specification.
| Property | Declared performance | Reference / standard |
|---|---|---|
| Thermal conductivity | 0.20 W/(m·K) | EN 12467+A2:2018 |
| Moisture movement | Max. 0.20% | EN 12467+A2:2018 |
| Water vapour diffusion factor | μ = 13.9 | EN 12467+A2:2018 |
| Thermal expansion coefficient | 0.0049 mm/mK | EN 12467+A2:2018 |
| Warm-water durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Soak/dry durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Freeze/thaw durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Heat/rain exposure | No visible cracking, delamination, warping or sagging observed | EN 12467+A2:2018 |
| Property | Standard format |
|---|---|
| Thickness | 6, 12 mm |
| Width | 800 mm |
| Length | 1.200 mm |
Availability can vary by order and destination. Confirm current formats, tolerances and minimum order quantities with Smartcon.
04 / Applications
Typical use areas listed by Smartcon. Final suitability depends on the complete assembly and project requirements.

05 / Assurance
Technical credibility depends on current documents and the performance of the complete installed system.
A1 — non-combustible according to EN 13501-1. This is the board’s reaction-to-fire classification, not a fire-resistance rating for a complete tiled assembly.
The board is one component of a wet-area assembly; waterproofing, adhesive, tile and joint systems must be selected together.
Document control
06 / Guidance
Smartbacker is intended as a fibre cement substrate beneath tiles, particularly in wet-area and framed-wall applications.
Smartbacker is supplied in 6 mm and 12 mm thicknesses, in an 800 × 1.200 mm compact format.
Yes. The underlying fibre cement product has an A1 reaction-to-fire classification under EN 13501-1.
Yes. Wet-area tile backing is included among the declared intended uses of the fibre cement product.
Adhesive, fixing centres, joints and waterproofing layers should be selected according to the complete installation system and project requirements.
Start a conversation
Tell us what you are specifying, where the project is located and the quantity you need. Our team usually responds within one business day.