High strength
Glass fibre mat and integrated core create a durable sheathing layer.
Building envelope / A1 non-combustible
A glass-fibre-mat-faced board with a moisture-resistant core for external walls, ventilated façades and cladding backer applications.

01 / Product overview
Smartsheath® is designed as a robust layer within modern building-envelope systems. Its distinctive green glass fibre mat and integrated core support weather exposure during construction, mould resistance and stable installation in horizontal or vertical orientation.
Request the latest technical documentation before final specification.
02 / Performance
Glass fibre mat and integrated core create a durable sheathing layer.
The specialised core is presented as resistant to bacteria, mould and fungus.
Declared A1 fire classification according to TS EN 13501-1.
Can receive the specified primer, basecoat and mineral finishing build-up.
Uniform strength supports horizontal or vertical installation.
Suited to façade repair and ventilated rainscreen assemblies.
Supports continuation of interior works when the envelope is appropriately detailed.
Can be cut with a utility knife according to the current product guidance.
03 / Data
Declared properties and standard formats.
| Property | Declared value | Reference / note |
|---|---|---|
| Average weight — 12.5 mm | 10.8 kg/m² | — |
| Average weight — 15 mm | 13.5 kg/m² | — |
| Shear strength | ≥ 1.000 N | — |
| Water absorption | ≤ 5% | TS EN 15283-1, H1 |
| Thermal conductivity | 0.25 W/mK | — |
| Fire resistance | A1 — non-combustible | TS EN 13501-1 |
| Property | Declared value | Reference / note |
|---|---|---|
| Thickness | 12.5, 15 mm | — |
| Width | 1.200 mm | — |
| Length | 2.400 mm | — |
Availability can vary by order and destination. Confirm current formats, tolerances and minimum order quantities with Smartcon.
04 / Applications
Typical use areas listed by Smartcon. Final suitability depends on the complete assembly and project requirements.

05 / Assurance
Technical credibility depends on current documents and the performance of the complete installed system.
A1 non-combustible according to TS EN 13501-1, as declared by Smartcon.
≤ 5% according to TS EN 15283-1, H1, as declared by Smartcon.
Wind loading, structural spans, membranes, fixings and cladding interfaces require project-specific verification.
Document control
06 / Guidance
The current product page refers to primer, basecoat and a mineral layer before painting. Use an approved, compatible full system.
The page describes fixing boards to a supporting metal framework. Framing, fixing centres, membranes and joints must follow current project documentation.
The current Smartcon guidance specifies a utility knife.
The current page specifies water-resistant mastic or paste. Confirm joint movement and compatibility across the complete external wall build-up.
Start a conversation