Reaction to fire
A1 — non-combustible according to EN 13501-1.
Architectural board / A1 non-combustible
A cement, cellulose and sand composite board for cladding, drywalls, ventilated façades, external walls and tile-backing applications.

01 / Product overview

Smartfiber® combines mineral durability with practical fabrication across regular, prefabricated, light-gauge steel and modular buildings. Its broad thickness and format range supports exterior envelope, interior lining and specialist substrate applications.
Request the latest technical documentation before final specification.
02 / Performance
A1 — non-combustible according to EN 13501-1.
Declared freeze/thaw and soak/dry durability: RL ≥ 0.75.
Tested for water impermeability, with no water drops observed.
Declared thermal conductivity: 0.20 W/(m·K).
Can serve as a backer board beneath ceramic tiles.
Can be cut and mechanically fixed using appropriate tools.
Suitable for prefabricated and steel-frame construction.
Listed in multiple widths, lengths and thicknesses for specification flexibility.
03 / Data
Declared properties and standard formats.
| Property | Declared performance | Reference / standard |
|---|---|---|
| Reaction to fire | A1 — non-combustible | EN 13501-1 |
| Type / category / class | NT / Category A / Class 2 | EN 12467+A2:2018 |
| Apparent density | ≥ 1.350 kg/m³ | EN 12467+A2:2018 |
| Bending strength | ≥ 7 N/mm² Wet condition — Category A/B | EN 12467+A2:2018 |
| Elastic performance | ≥ 8.000 N/mm² — length ≥ 6.000 N/mm² — width | EN 12467+A2:2018 |
| Water impermeability | No water drops observed | EN 12467+A2:2018 |
Declared values are based on the manufacturer’s current Declaration of Performance and applicable test documentation. Project-specific suitability should be verified against the latest technical documentation before specification.
| Property | Declared performance | Reference / standard |
|---|---|---|
| Thermal conductivity | 0.20 W/(m·K) | EN 12467+A2:2018 |
| Moisture movement | Max. 0.20% | EN 12467+A2:2018 |
| Water vapour diffusion factor | μ = 13.9 | EN 12467+A2:2018 |
| Thermal expansion coefficient | 0.0049 mm/mK | EN 12467+A2:2018 |
| Warm-water durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Soak/dry durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Freeze/thaw durability | RL ≥ 0.75 | EN 12467+A2:2018 |
| Heat/rain exposure | No visible cracking, delamination, warping or sagging observed | EN 12467+A2:2018 |
| Property | Declared performance | Reference / standard |
|---|---|---|
| Thickness tolerance | ±10% of board thickness | EN 12467+A2:2018 |
| Length tolerance | ±5 mm | EN 12467+A2:2018 |
| Width tolerance | ±3.75 mm | EN 12467+A2:2018 |
| Perpendicularity | ≤ 2 mm/m | EN 12467+A2:2018 |
| Dimensional tolerance | Level 1 | EN 12467+A2:2018 |
| Property | Declared value | Reference / note |
|---|---|---|
| Thickness | 6, 8, 10, 12, 14, 16, 18, 20 mm | — |
| Width | 1.200, 1.250 mm | — |
| Length | 2.500, 2.800, 3.000 mm | — |
Availability can vary by order and destination. Confirm current formats, tolerances and minimum order quantities with Smartcon.
04 / Applications
Typical use areas listed by Smartcon. Final suitability depends on the complete assembly and project requirements.

05 / Assurance
Technical credibility depends on current documents and the performance of the complete installed system.
A1 — non-combustible according to EN 13501-1. This is the board’s reaction-to-fire classification, not a fire-resistance rating for a complete assembly.
EN 12467+A2:2018: Type NT, Category A, Class 2. Bending strength is declared as ≥ 7 N/mm² in wet condition for Category A/B.
Request the current Declaration of Performance and applicable conformity documentation before specification. Confirm the certification scope for the supplied thickness.
Document control
06 / Guidance
Apply a compatible water-based acrylic paint after installation, following current board and coating-system guidance.
The current page describes a supporting metal framework with boards screwed directly to it. Project-specific framing, fixings, joints and weather protection require the latest system documentation.
The current guidance lists a diamond-headed spiral saw or a fiber cement knife. Use appropriate extraction and respiratory protection.
The current page refers to mastic or paste. Select a compatible joint treatment suited to movement, exposure and the final finish.
Start a conversation
Tell us what you are specifying, where the project is located and the quantity you need. Our team usually responds within one business day.